Volume 103, Issue 7 pp. 1093-1100
ORIGINAL ARTICLE - CLINICAL SCIENCE

Comparisons of noncoronary sinus pivot implantation (NCPI) and conventional method for transcatheter aortic valve replacement with self-expanding valve in pure aortic regurgitation (PAR)

Lifan Yang MD

Lifan Yang MD

Department of Cardiology, Zhongshan Hospital, Fudan University Minhang Meilong, Shanghai, China

National Clinical Research Center for Interventional Medicine, Shanghai, China

Search for more papers by this author
Shasha Chen MD

Shasha Chen MD

National Clinical Research Center for Interventional Medicine, Shanghai, China

Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, China

Search for more papers by this author
Xiaochun Zhang MB

Xiaochun Zhang MB

National Clinical Research Center for Interventional Medicine, Shanghai, China

Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, China

Search for more papers by this author
Yuan Zhang MD

Yuan Zhang MD

National Clinical Research Center for Interventional Medicine, Shanghai, China

Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, China

Search for more papers by this author
Daxin Zhou MD

Corresponding Author

Daxin Zhou MD

National Clinical Research Center for Interventional Medicine, Shanghai, China

Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, China

Correspondence Wenzhi Pan, MD and Daxin Zhou, MD, Department of Cardiology, Zhongshan Hospital, Fudan University, No. 180, Fenglin Rd, Shanghai 200032, China.

Email: [email protected] and [email protected]

Search for more papers by this author
Wenzhi Pan MD

Corresponding Author

Wenzhi Pan MD

National Clinical Research Center for Interventional Medicine, Shanghai, China

Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, China

Correspondence Wenzhi Pan, MD and Daxin Zhou, MD, Department of Cardiology, Zhongshan Hospital, Fudan University, No. 180, Fenglin Rd, Shanghai 200032, China.

Email: [email protected] and [email protected]

Search for more papers by this author
Junbo Ge MD

Junbo Ge MD

National Clinical Research Center for Interventional Medicine, Shanghai, China

Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, China

Search for more papers by this author
First published: 01 May 2024

Abstract

Background:

As compared to treatment of aortic stenosis (AS), transcatheter aortic valve replacement (TAVR) using the commercially available valves to treat pure aortic regurgitation (PAR) has a lower device success rate and higher complication rates.

Aims

The study compared the acute results between TAVR using a novel noncoronary sinus pivot implantation (NCPI) method and that using the conventional method, aiming to explore a more optimized and effective operation method for TAVR in PAR.

Methods

PAR patients who underwent TAVR with self-expanding valves in our center from September 2021 to September 2023 were enrolled were divided into the NCPI (group A, N = 16) and conventional method (group B, N = 39) groups. We analyzed the pre-operative evaluation parameters and procedural and postoperative data of the two subgroups.

Results

The total patients’ mean age was 71.2 ± 8.7 years and most were male (61.8%), with a mean Society of Thoracic Surgeons score of 3.4 ± 1.9%. The device success rate of groups A and B was 100% and 71.8%, respectively. In group B, 48.7% had major adverse cardiac events (MACE); 46.2% patients had permanent pacemaker implantation or valve in valve implantation. None had MACE in group A. The noncoronary sinus implantation depth in NCPI was −1.1 + 1.0 and 4.2 + 3.7 mm in groups A and B (p < 0.001), respectively.

Conclusions

TAVR with a self-expanding valve using the NCPI method had a higher procedure success rate and dramatically low complications than that using the conventional method in PAR patients.

CONFLICT OF INTEREST STATEMENT

The authors declare no conflict of interest.

DATA AVAILABILITY STATEMENT

The data that support the findings of this study are available from the corresponding author upon reasonable request.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.