Volume 40, Issue 1 pp. 66-74
Technical Note

Validation of a new UNIX-based quantitative coronary angiographic system for the measurement of coronary artery lesions

Malcolm R. Bell MBBS, FRACP

Corresponding Author

Malcolm R. Bell MBBS, FRACP

Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic and Mayo Foundation, Rochester, Minnesota

Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905Search for more papers by this author
Paula J. Britson BS

Paula J. Britson BS

Information Services Division of Clinical Applications, Mayo Clinic and Mayo Foundation, Rochester, Minnesota

Search for more papers by this author
Aloysius Chu MS

Aloysius Chu MS

Information Services Division of Clinical Applications, Mayo Clinic and Mayo Foundation, Rochester, Minnesota

Search for more papers by this author
David R. Holmes Jr. MD

David R. Holmes Jr. MD

Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic and Mayo Foundation, Rochester, Minnesota

Search for more papers by this author
John F. Bresnahan MD

John F. Bresnahan MD

Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic and Mayo Foundation, Rochester, Minnesota

Search for more papers by this author
Robert S. Schwartz MD

Robert S. Schwartz MD

Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic and Mayo Foundation, Rochester, Minnesota

Search for more papers by this author

Abstract

We describe a method of validation of computerized quantitative coronary arteriography and report the results of a new UNIX-based quantitative coronary arteriography software program developed for rapid on-line (digital) and off-line (digital or cinefilm) analysis. The UNIX operating system is widely available in computer systems using very fast processors and has excellent graphics capabilities. The system is potentially compatible with any cardiac digital x-ray system for on-line analysis and has been designed to incorporate an integrated database, have on-line and immediate recall capabilities, and provide digital access to all data. The accuracy (mean signed differences of the observed minus the true dimensions) and precision (pooled standard deviations of the measurements) of the program were determined x-ray vessel phantoms. Intra- and interobserver variabilities were assessed from in vivo studies during routine clinical coronary arteriography. Precision from the x-ray phantom studies (6-in. field of view) for digital images was 0.066 mm and for digitized cine images was 0.060 mm. Accuracy was 0.076 mm (overestimation) for digital images compared to 0.008 mm for digitized cine images. Diagnostic coronary catheters were also used for calibration; accuracy varied according to size of catheter and whether or not they were filled with iodinated contrast. Intra- and interobserver variabilities were excellent and indicated that coronary lesion measurements were relatively user-independent. Thus, this easy to use and very fast UNIX based program appears to be robust with optimal accuracy and precision for clinical and research applications. Cathet Cardiovasc Diagn 40:66–74, 1997 © 1997 Wiley-Liss, Inc.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.